Current page:

Home

/

News

/

General requirements and anti-static measures for anti-static in pcb assembly online welding

General requirements and anti-static measures for anti-static in pcb assembly online welding

Pcb assembly online welding is one of the important reasons for generating electrostatic electrical overload EOS. The antistatic measures in manual soldering are as follows.
1) pcb assembly online soldering tools must be well grounded, use qualified anti-static tools
1 Tools such as soldering irons and soldering irons must be well grounded.
2 Eliminate the use of ordinary plastic screw drivers, plastic suction devices, nylon brushes, and label items consisting of layers of insulating material to prevent static build-up.

2) Identify anti-static labels and signs
Identify anti-static labels and signs. SSD production plants or imported static sensitive materials are usually labeled with special labels on SSD packaging. Labels are usually printed in orange to alert you.
3) All operations of static sensitive components must be performed on an antistatic workbench
1 In order to prevent EOS/ESD damage to SSD, all operations, pcb assembly online, and testing must be performed on an anti-static workbench.
2 Try to avoid sensitive components moving inside the package to generate static electricity.
3 Assembly without static-sensitive component markings should also be operated as a static-sensitive assembly.
4) Stack the assembled boards to prevent mechanical damage
The assembled plates to be welded and welded shall be placed on the anti-static printed board frame and the turnover box one by one to prevent mechanical damage.
5) Protect processed products
The tested and inspected electronic assembly board is sprayed once with an ion gun before sealing to eliminate the static charge that may accumulate.